Section 2 Operations and Maintenance

Page 2-325

© 2000, ADC Telecommunications, Inc.

DLP-779

Page 2 of 3

Table 779-1. 2488 RIC Card Status Definitions

ITEM

STATUS

DEFINITION

ACTION

CARD

Operational
State

Up

Down

Unknown

Card is functioning properly.

Card is not functioning properly, is
in reset mode, or failed. Check
Admin state.

The system processor does not
currently know the operational
status.

No action required.

Verify card is installed,
check for failure indications or
provision card for service per DLP-
756.

Wait a few seconds for system to
complete its operations and then
update the screen.

Availability
State

Available

In Test

Failed

PowerOff

Not Installed

Offline

Dependency

Unknown

Card is ready for processing
commands.

Card is currently processing test
signals.

Card has failed operation and
system has placed it out of service.

No power to the card.

Card is not installed.

Card is installed and provisioned
but currently off line.

Card is supplying timing reference,
traffic, or other data to the system.

The system processor does not
currently know the availability
status.

No action required.

Wait a few seconds for screen to
update.

Card may be performing a reset, or
the bus may be busy.

Check power source. Replace card if
source is good per DLP-777.

If required, install card in selected
slot per DLP-777 and provision per
DLP-756.

If required, set module on line per
DLP-756.

Perform a soft switch over (manual)
per DLP-771 to release card
dependency if removing.

Wait for processor to update current
status, may need to perform a
manual reset of SC per DLP-773.

PORT

Section
Status

No Alarm

LOS

LOF

No errors between local and next
node.

Loss Of Signal, cannot locate
section data.

Loss Of Frame, cannot locate
frame bit of section data.

No action required.

Check connectors, fiber, and
transmitter at other end.

Check signal type, and power level
of received signal.

Line Status

No Alarm

AIS

RDI

Receiving good input signal

Alarm Indication Signal, inserted
all 1s or blue signal at originating
node.

Remote Defect Indicator.

No action required.

Check signal status at traversing
nodes, and low speed signal input at
transmitting node.

Problem at the far end.

(continued)