1152700

Issue 1

February 2001

Section 2 Operation and Maintenance

Page 2-255

© 2000, ADC Telecommunications, Inc.

DLP-755

Page 4 of 5

Table 755-1. T1 Multi 1 Configuration Options, continued

SELECTION

DEFAULT

OPTIONS

DEFINITIONS

Loopback Config

None

None

Facility Payload

Terminal

Facility Line

No loopback activated on this card.

Loops the payload after line data is
extracted.

Sends cells to the cellbus and back to the
ring. No changes are made to the payload.

Loops the incoming signal back to CPE,
generates AIS to the cellbus.

Circuit Identifier

<blank>

Up to 20 alphanumeric
characters.

User defined. Usually describes the traffic,
customer, and/or channel number.

Table 755-2. ATM Interface Configuration Options for CRS Mode

SELECTION

DEFAULT

OPTIONS

DEFINITIONS

Interface Name

<default>

Alphanumeric

User defined, up to 20 alpha numeric
characters.

Loopback Location Code

All 1s

Alphanumeric

Used to loopback the incoming signal and
transmit it back to the customer equipment.
The code is limited to 16 numeric
characters.

Recording Interface ID

All 0s

Numeric

Identifies the site card and port location for
customer billing capabilities, (allows
assignment of a customer ID for each port.)
The code is limited to 15 numeric
characters.

Provisioned Endpoints

Displays how many VPC or VCC endpoints
are configured by administrator on this card.

Interface Type

UNI

UNI
NNI

Specifies interface type as User to Network
Interface or Network to Network Interface.

CAC Formula

PCR

PCR Based
SCR Based

Specifies Peak Cell Rate or Sustained Cell
Rate for Connection Admission Control.

Policing

Off

On or Off

User sets whether traffic will be policed for
Quality Of Service (QOS).

Cell Scrambling

Off

On or Off

User sets whether traffic will be scrambled.

Over Subscription Rate

<blank>

User sets depending on traffic contract.

Max Active VPI Bits

0

0 to 8

Sets the maximum number of bits that may
be utilized from this port.

Max Active VCI Bits

0

0 to 12

Sets the maximum number of bits that may
be utilized from this port.

Max number of VPCs

256

0 to 256

Sets the maximum number of VPCs that
may be utilized from this port.

Max number of VCCs

0

0-8192

Sets the maximum number of VCCs that
may be utilized from this port.