ADC Release 3.1 User Manual

Page 481

Advertising
background image

1152700

Issue 1

February 2001

Section 2 Operations and Maintenance

Page 2-437

© 2000, ADC Telecommunications, Inc.

TAP-100

Page 18 of 23

Table 4-1. Alarm Identifications, continued

ALARM
MESSAGE

SEVERITY

IMPACT

DESCRIPTION

SUGGESTED COURSE OF ACTION

Shelf
Controller
EIM 1
Removed

EIMSlot1R
emoved

Informational
Alert

Installation
Information

SC EIM in slot one which
provides hardwired alarm
inputs and outputs, remote
ACO activation, and
timing reference inputs
(BITS), cannot be found .

Buses are probably not
functioning properly because
the Bus Terminating EIM (B-
TEIM) in slot 18 at the rear of
the shelf or the SC in slot 1 has
been physically removed from
the backplane.

Shelf
Controller
EIM 18
Removed

EIMSlot18
Removed

Informational
Alert

Installation
Information

SC EIM in slot 18 which
provides backplane bus
termination, Telnet
connection to the node,
and shelf addressing, has
been physically pulled
from the backplane.

Buses are probably not
functioning properly because
the Bus Terminating EIM (B-
TEIM) in slot 18 at the rear of
the shelf or the SC in slot 18
has been physically removed
from the backplane.

Signal
Degraded

Minor

Could be
Service
Affecting.

Input signal strength is
degraded. Possibly a fiber
problem or transmitter.

Check fiber path for damage or
bends and check attenuation
and transmitter output.

Software
Downloadi
ng Failed

SWDownlo
adFailed

Informational
Alert

Installation
Information

NMIC unable to
download software
successfully to the NE.

Check FTP connection and NE
status.

Sync
Message
Changed

SyncMessa
geChanged

Major –
currently an
informational
alert.

Installation
Error

SONET sync message (S1
byte) changed.

No suggestions.

Sync
Reference
Failure

SyncRefere
nceFailed

Major –
currently an
informational
alert.

Service
Affecting

Timing reference that the
network element clocks
off of has failed.

Retrieve timing source
information and check reference
input (BITS, 622-RIC, 155-
CRS).

T1
Loopback

DS1Loopba
ck

Informational
Alert

Service
Affecting

T1 Loopback Pseudo
Random Pattern. Indicates
a loopback condition has
been initiated by a user.

Check for troubleshooting
activity by other users and
release loopback if necessary.

T1 Yellow
Alarm

DS1Rai

Minor

Not service
affecting

DSX1 Alarm: Remote
Alarm Indication.
Indicates a problem at the
CPE transmitter.

Check card and output level of
CPE equipment. Replace as
needed per local practices.

(continued)

Advertising