Dlp-762, Page 2 of 6, Item status definition action – ADC Release 3.1 User Manual

Page 296

Advertising
background image

1152700

Issue 1

February 2001

Section 2 Operations and Maintenance

Page 2-276
© 2000, ADC Telecommunications, Inc.

DLP-762

Page 2 of 6

Cellworx Vision: Card View - T3 TMUX Multi 1 Mother Card

Status:

Apply

Chassis View

Refresh

Close

X

Card Level

Operational State:
Availability State:
Protection State:

Port Level

Status

Active

Protect

1

Port

ADC

T3 TMUX

MULTI 1

Up
Available
Unknown

Line State:

Configuration:

Port Level

Recieve:

No Alarm

RCV RAI Failure

Xmt RAI Alarm

Rcv AIS

Xmit AIS

LOF

LOS

Loopback State

Rcv Test Code

Other:

Status

Active

Protect

ADC

TMUX

EXP

Slot: 3

Slot: 4

APPLIES CHANGES
AND SENDS TO SHELF
CONTROLLER.

RETURNS TO CHASSIS
VIEW WITHOUT CLOSING
CARD LEVEL VIEW.

REPAINTS WINDOW
TO REFLECT ANY
CHANGES.

CLOSES CARD LEVEL
VIEW AND RETURNS TO
SHELF LEVEL VIEW.

CLICK ON BOX AND DRAG
UP OR DOWN TO EXPAND
STATUS OR CONFIGURATION
VIEWS.

13436-B

DS3 Port

DS1 Channel

Transmit:

NE Name: Cellworx1
NE Id: 1
Card: T3 TMUX MULTI 1 / TMUX E
Slot Number: 3 / 4
Port Number: 1
Channel Number:

1

Figure 762-1. T3 TMUX Multi 1/TMUX EXP Card Status Window

Table 762-1. Display T3 TMUX Multi 1 and TMUX EXP Card Status Definitions

ITEM

STATUS

DEFINITION

ACTION

Operational
State

Up

Down

Unknown

Card is functioning properly.

Card is not functioning
properly, is in reset mode, or
failed. Check Admin state.

The shelf controller does not
currently know the
operational status.

No action required.

Verify card is installed, check for
failure indications, or provision card
for service per DLP-754.

Wait a few seconds for operations to
complete and update the screen.

(continued)