ADC Release 3.1 User Manual

Page 282

Advertising
background image

1152700

Issue 1

February 2001

Section 2 Operation and Maintenance

Page 2-262
© 2000, ADC Telecommunications, Inc.

DLP-757

Page 3 of 3

Table 757-1. Shelf Controller Status Definitions, Continued

ITEM

STATUS

DEFINITION

ACTION

Synchronization
State

Locked

Unlocked

Card is currently in sync with the
reference source.

Card is not currently in sync with
reference source.

No action required.

Allow a minimum of 5
minutes for cards to sync up
to reference, then check
configuration and monitor
source.

Alarms
Acknowledged

No

Yes

Alarm Cut Off condition is not
currently active.

Alarm Cut Off has been initiated to
silence audible alarms.

No action required.

ACO will deactivate upon a
new alarm condition. Ativate
if required per DLP-776 .

Timing
Reference

DB7

DB8

Both Buses

None

SC is providing clock for cell bus
7.

SC is providing clock for Cell bus
8.

SC is providing clock for both cell
buses.

SC is not providing clock reference
to any cell bus.

No action required. If a card
will be removed, it is best to
perform a switch over to the
stand-by card first. Refer to
DLP-771.

TX
Synchronization
Signal Status

ST3
PRS
STU
ST2
SMC
DUS

Non-Configurable. Indicates the
quality of the SC clock signal to
the shelf. TX Sync Status should
match RX Sync Status if SC is
locked to the timing reference.
Status will show DUS while it is
acquiring to the reference, and
transmit ST3 while in holdover.

No action required. To select
a different timing source,
refer to DLP-749.

Table 757-2. Timing Reference Status Definitions

STATUS

DEFINITION

PRC
PRS
SEC
SSU
ST1
STU
ST2
ST3
SMC
DUS

SDH Primary Reference Clock
Primary Reference Source
SDH Equipment Clock Traceable
SDH Sync Supply Unit Traceable
Stratum 1 level source
Synchronized Traceability Unknown
Stratum 2 level source
Stratum 3 level source
SONET Minimum level Clock
Reference cannot be used for source