ADC Release 3.1 User Manual

Page 475

Advertising
background image

1152700

Issue 1

February 2001

Section 2 Operations and Maintenance

Page 2-431

© 2000, ADC Telecommunications, Inc.

TAP-100

Page 12 of 23

Table 4-1. Alarm Identifications, continued

ALARM
MESSAGE

SEVERITY

IMPACT

DESCRIPTION

SUGGESTED COURSE OF ACTION

Module
Failure
without
protection

ModuleFail

Critical

Service
Outage /
RICs have
outage only
on dual
failure.

Card failure or card
malfunction.

Reset the card via software,
reseat the card to reboot it. If it
does not return to service,
replace the card. Call ADC for
warranty information and
return authorization.

Module
Failure
Stand-by
Ring
Interface
Card
(RIC)

ModuleFail

Major

Not Service
affecting.
RICs have
outage only
on dual
failure.

Card failure or card
malfunction.

Reset the card via software,
reseat the card to reboot it. If it
does not return to service,
replace the card. Call ADC for
warranty information and
return authorization.

Module
Failure
with
protection

ModuleFail

Minor

Not service
affecting.

Card failure or card
malfunction.

Reset the card via software,
reseat the card to reboot it. If it
does not return to service,
replace the card. Call ADC for
warranty information and
return authorization.

NE Power
Failure (A)

Power“X”Fa
ilure (X = A
or B)

Critical –
currently an
information
al alert.

Service
Outage

An input power failure on
either the A side, or B side
of the shelf.

Check power supplies,
breakers, and fuses. Investigate
if anything in the equipment
caused a breaker trip or blown
fuse. Verify peroper ratings for
current draw.

New
SONET
Path Trace

NewPathTr
ace

Information
al Alert

Not Service
Affecting

New SONET path trace has
been received.

Informs the user that a new
path trace has been established
in the network, probably a new
connection. No action
necessary.

Optical
Laser
Failure

LaserFail

Critical/

Major on
RIC

Service
Outage
except on
RIC cards.

Optical LASER failure at
card/port reported in alarm
message.

May try resetting or reseating
card but generally a hard
failure. Replace card. See
Section 6 of this manual for
warranty and return
authorization information.

(continued)

Advertising