SET 622 SM CRS CARD CONFIGURATION

Summary: This procedure details the steps required to set the 622 SM CRS card configurations
utilizing the Cellworx STN Phase 3.1 shelf level Graphical User Interface (GUI). Configuration
can be set for the card, port and ATM interface on individual ports. This procedure is divided
into two sections with the second section dealing with the ATM interface screens. The user must
have the GUI launched and accessed the shelf level GUI display per NTP-006 prior to
performing this procedure.

1.

CARD AND PORT CONFIGURATION

1. Double click on the 622 SM CRS card displayed in the shelf level GUI “Chassis View”at

the top of the window.

2. The 622 SM CRS card display appears as shown in Figure 797-1. Click on the port to be

configured (Port 1 or 2) located on the simulated card on the left side of the window.

3. Click and drag the small block upward to expand the Configuration section of the window

so all options are visible. The Administrative State of the card and port should be
“Unlocked” if in service. If “Locked”, select the “Unlocked” option using the left mouse
button to enable the port for service.

4. At Timing Port, select the port that will be used as a reference if this slot is selected as a

timing source from the Timing Resource Screen.

5. If this card and port are being utilized as an expansion shelf interface (either from ring to

EPS, or EPS to ring), select the Expansion Shelf Interface button.

6. Set the Port Level configuration options per requirements. Refer to Table 797-1 for a list of

options the user may select for this card type.

7. Hit the Apply button at the bottom of the window to back up the new configuration data to

the shelf controller.

Note: Selecting Chassis View will return the user to the previous window without
closing the 622 SM CRS window. Selecting Refresh will update the current window
display and all the selections last recorded by the Shelf Controller card. Selecting Close
will close this window.

2.

ATM INTERFACE CONFIGURATION

8. Double click on port 1. The ATM interface screen appears. Refer to the example shown in

Figure 797-2.

9. Set the ATM options as needed using Table 797-2 as a reference.

Advertising