Section 2 Operation and Maintenance

Page 2-261

© 2000, ADC Telecommunications, Inc.

DLP-757

Page 2 of 3

Table 757-1. Shelf Controller Status Definitions

ITEM

STATUS

DEFINITION

ACTION

Operational
Status

Up

Down

Unknown

Card is installed and functioning
properly.

Card is not functioning properly, is
in reset mode, or failed.

The system processor does not
currently know the operational

No action required.

Verify card is installed,
check for failure indications
and alarms.

Wait a few seconds for
system to complete its
operations and then update
the screen.

Availability
State

Available

Unavailable

In Test

Failed

Power off

Not Installed

Offline

Dependency

Unknown

Card is ready for processing
commands.

Card is in standby mode or busy
processing commands.

Card is currently in a test mode.

Card requires operator
intervention.

No power is applied to card.

Card is not physically installed into
the backplane.

Card is installed but not in service.

Card is supplying timing reference,
traffic, or other data to the system.

The system processor does not
currently know the availability
status.

No action required.

Wait a few moments and
recheck status.

Wait a few moments and
recheck status.

On site replacement of failed
SC card. Refer to DLP-777.

Check power source. Replace
card if necessary per DLP-777.

Try other SC card slot, install
missing card if required. Per
DLP-777.

No action required.

Perform a soft switch over
(manual) per DLP-771 to
release card dependency if
removing.

Wait for processor to update
current status, may need to
perform a card reset per DLP-
773.

Protection State

Enabled

Not Protected

Protection operation is supported.

No protection card is available.

No action required.

Add or replace the inactive
SC card per DLP-777.

(continued)