Dlp-756, Page 2 of 3, Selection default options definition – ADC Release 3.1 User Manual

Page 278

Advertising
background image

1152700

Issue 1

February 2001

Section 2 Operation and Maintenance

Page 2-258
© 2000, ADC Telecommunications, Inc.

DLP-756

Page 2 of 3

Cellworx Vision: Card View - 622 Ring Interface Card

Status:

Apply

Chassis View

Refresh

Status

Active

Protect

Timing

Close

X

Configuration:

Card Level

Administrative State: Congestion Thresholds:

Locked

Unlocked

Ingress:

Egress:

80

80

%

%

Port Level

Administrative State: Transmit Timing Source:

Locked

Unlocked

System

Recieved

NE Name: Cellworx1

NE Id: 1

Card: 622 Ring

Slot Number: 17

Port Number: 1

Port

ADC

2488
Ring

1

Status

Active

Timing

NE1_slot17_Port1(RIC)

Do not use for synchronization

SONET

Medium Type:

SDH

Loopback towards:

None

Terminal

Facility

Transmit Path Trace:

Diagnostics

Line Coding:

Line Type:

sonetMediumNRZ

sonetLongSingleMode

APPLIES CHANGES
AND SENDS TO SHELF
CONTROLLER.

RETURNS TO CHASSIS
VIEW WITHOUT CLOSING
CARD LEVEL VIEW.

REPAINTS WINDOW
TO REFLECT ANY
CHANGES.

CLOSES CARD LEVEL
VIEW AND RETURNS TO
SHELF LEVEL VIEW.

PERFORMS TEST
OVER FIBER
LINK.

CLICK ON BOX AND DRAG
UP OR DOWN TO WIDEN
STATUS OR CONFIGURATION
VIEWS.

CLICK ON BOX AND DRAG UP
OR DOWN TO WIDEN PORT
LEVEL VIEW.

USE SLIDERS TO VIEW
HIDDEN SELECTIONS.

PORT LEVEL
CONFIGURATION OPTIONS.

CARD LEVEL
CONFIGURATION OPTIONS.

NE AND CARD TYPE/
SLOT INFORMATION.

CARD REPRESENTATION
WITH REAL TIME ALARM
INDICATIONS.

Ring Selection :

Auto

Ring 16

Ring 17

Enabvle signal degrade

0026-050

Figure 756-1. 2488 RIC Shelf Level GUI Configuration Screen

Table 756-1. 2488 RIC Card Configuration Options

SELECTION

DEFAULT

OPTIONS

DEFINITION

Admin State

Unlock

Lock / Unlock

Not configurable on RIC.

Congestion
Threshold

80

0-100

Percentage of buffer capacity that will cause a
congestion threshold notification.

Ring
Selection

Auto

Auto
Ring 16
Ring 17

Not configurable on RIC.

Transmit
Timing
Source

System

System

Received

Uses Primary timing reference.

Uses clock derived from incoming receive fiber (also
known as Line-Timing).

Do Not Use
for Sync

False

Selected (true)

Not selected
(false)

If “True”, causes the RIC to output DUS (Do not Use
for Sync) in the S1 byte of the SONET overhead.

Enable Signal
Degrade

Not Selected

Selected

Not Selected

Enables a protection switch of the traffic if the input
signal strength drops below tolerable levels set by the
user in the BER threshold selection.

(continued)

Advertising