Section 2 Operation and Maintenance

Page 2-273

© 2000, ADC Telecommunications, Inc.

DLP-761

Page 2 of 3

Table 761-1. T3 CRS Card Status Definitions

ITEM

STATUS

DEFINITION

ACTION

Operational
State

Up

Down

Unknown

Card is functioning properly.

Card is not functioning properly,
is in reset mode, or failed. Check
Admin state.

The shelf controller does not
currently know the operational
status.

No action required.

Verify card is installed, check for
failure indications, or provision card
for service per DLP-753.

Wait a few seconds for operations to
complete and update the screen.

Availability
State

Available

In Test

Failed

Power Off

Not Installed

Off Line

Dependency

Unknown

Card is ready for processing
commands.

Card is currently processing test
signals.

Card has failed operation and
system has placed it out of
service.

No power to the card.

Card is not currently installed in
selected slot of the shelf.

Card is installed and provisioned
but currently off line.

Card is supplying timing
reference, traffic, or other data to
the system.

The system processor does not
currently know the availability
status.

No action required.

Wait a few seconds for screen to
update.

Card may be performing a reset, or
the bus may be busy.

Check power source, replace card if
source is good.

If required, install card in selected
slot per DLP-777 and provision per
DLP-753.

If required, set module on line per
DLP-753.

Perform a soft switch over (manual)
per DLP-771 to release card
dependency if removing.

Wait for processor to update current
status, may need to perform a
manual reset of SC per DLP-773.

Protection State

Not
Protected

Enabled

Manual
switch

Forced
Switch

Lockout

Unknown

Not Protected

Protection is available for
selected card but is not active.

User has manually switched the
card to protection.

User has forced card to
protection.

Card cannot switch to protection.
It has been locked out by
command or switch count.

Protection status information is
not available to the shelf
controller.

If equipped, set up a protection
group and provision card for
protection per DLP-765.

No action necessary.

If required, switch the card back per
DLP-771.

If required, release forced switch per
DLP-771.

If required, release manual lock-out
per DLP-771.

Wait a few minutes and update
screen. May need to reset SC, refer
to DLP-773.

(continued)