Dlp-751, Page 2 of 3, Selection default options definition – ADC Release 3.1 User Manual

Page 255

Advertising
background image

1152700

Issue 1

February 2001

Section 2 Operation and Maintenance

Page 2-235

© 2000, ADC Telecommunications, Inc.

DLP-751

Page 2 of 3

Cellworx Vision: Card View - 622 Ring Interface Card

Status:

Apply

Chassis View

Refresh

Status

Active

Protect

Timing

Close

X

Configuration:

Card Level

Administrative State: Congestion Thresholds:

Locked

Unlocked

Ingress:

Egress:

80

80

%

%

Port Level

Administrative State: Transmit Timing Source:

Locked

Unlocked

System

Recieved

NE Name: Cellworx1

NE Id: 1

Card: 622 Ring

Slot Number: 17

Port Number: 1

Port

ADC

622

Ring

1

Status

Active

Timing

Do not use for synchronization

SONET

Medium Type:

SDH

Loopback towards:

None

Terminal

Facility

Diagnostics

Line Coding:

Line Type:

sonetMediumNRZ

sonetLongSingleMode

APPLIES CHANGES
AND SENDS TO SHELF
CONTROLLER.

RETURNS TO CHASSIS
VIEW WITHOUT CLOSING
CARD LEVEL VIEW.

REPAINTS WINDOW
TO REFLECT ANY
CHANGES.

CLOSES CARD LEVEL
VIEW AND RETURNS TO
SHELF LEVEL VIEW.

PERFORMS TEST
OVER FIBER
LINK.

CLICK ON BOX AND DRAG
UP OR DOWN TO WIDEN
STATUS OR CONFIGURATION
VIEWS.

CLICK ON BOX AND DRAG UP
OR DOWN TO WIDEN PORT
LEVEL VIEW.

USE SLIDERS TO VIEW
HIDDEN SELECTIONS.

622 MBPS PORT LEVEL
CONFIGURATION OPTIONS.

CARD LEVEL
CONFIGURATION OPTIONS.

NE AND CARD TYPE/
SLOT INFORMATION.

CARD REPRESENTATION
WITH REAL-TIME ALARM
INDICATIONS.

13443-B

Ring Selection :

Auto

Ring 16

Ring 17

Enable signal degrade

Signal Degrade BER Threshold: 10E- 5

Figure 751-1. 622 RIC Shelf Level GUI Configuration Screen

Table 751-1. 622 RIC Card Configuration Options

SELECTION

DEFAULT

OPTIONS

DEFINITION

Admin State

Unlock

N/A

Not Configurable on RIC

Congestion
Threshold

80

0-100

Percentage of buffer capacity that will cause a
congestion threshold notification for Ingress and Egress.

Ring
Selection

Auto

N/A

Not Configurable on RIC

Transmit
Timing
Source

System

System

Received

Uses Primary timing reference.

Uses clock derived from incoming receive fiber (also
known as Line-Timing).

Do Not Use
for Sync

False

Selected
(true)

Not selected
(false)

If “True”, causes the RIC to output DUS (Do not Use for
Sync) in the S1 byte of the SONET overhead.

Enable Signal
Degrade

Not Selected

Selected

Not Selected

Enables a protection switch of the traffic if the input
signal strength drops below tolerable levels set by the
user in the BER threshold selection.

(continued)