Dlp-749, Reference should not be used for source, Page 2 of 3 – ADC Release 3.1 User Manual

Page 250: Continued)

Advertising
background image

1152700

Issue 1

February 2001

Section 2 Operation and Maintenance

Page 2-230
© 2000, ADC Telecommunications, Inc.

DLP-749

Page 2 of 3

Cellworx Vision: Timing Resource

Apply

Chasis View

Refresh

Close

X

Node Name: Cellworx1

Node Id: 1

Primary:

DS1 Output Source

Timing Reference:

Secondary:

None

Enable

APPLIES CHANGES
AND SENDS TO SHELF
CONTROLLER.

RETURNS TO CHASSIS
VIEW WITHOUT CLOSING
CURRENT WINDOW.

REPAINTS WINDOW
TO REFLECT ANY
CHANGES.

CLOSES CARD LEVEL
VIEW AND RETURNS TO
CHASSIS LEVEL VIEW.

13482-C

Status:

Current Timing Reference:

Protection Status:

Active Sync Status:

Alternate Sync Status:

Primary

Enabled

ST3

ST3

Configuration:

TX Sync Status:

FDL Receive:

Frame Format:

Encoding Rule:

Slot 16

N/A

Enabled

Disab

N/A

ESF

S

N/A

BSF

A

DS1 Output Source:

DS1 Transmit Mode:

AIS Threshold:

N/A

N/A

None

Protection:

Switch Command:

Revertive

Non Revertive

Manual

Protection Mode:

Revert Time:

0

Figure 749-2. Shelf Level GUI Timing Resource Configuration Window

Table 749-1. Timing Resource Configuration Options

SELECTION

(PRIMARY OR SECONDARY)

DEFAULT

OPTIONS

DEFINITIONS

Timing Reference

Internal

BITS Primary

BITS Secondary

Internal

Slot XX

Hardwired in at SC EIM at CO.

Hardwired in at SC EIM at CO.

Uses internal Stratum 3 source.

Uses any optical interface, DS3 running in
PLCP mode, or an E1 card (XX=slot#).

DS1 Output Source

None

Slot XX

None

Derives a T1 from a received optical signal
of slot specified (XX=slot#).

No source selected for output.

TX Sync Status

N/A

PRS

ST2

ST3

SMC

DUS

Primary Reference Source

Stratum 2 level source

Stratum 3 level source

SONET Minimum level Clock

Reference should not be used for
source.

(continued)

Advertising