ADC Release 3.1 User Manual

Page 178

Advertising
background image

1152700

Issue 1

February 2001

Section 2 Operation and Maintenance

Page 2-158

2000, ADC Telecommunications, Inc.

DLP-729

Page 4 of 4

Table 729-1. T1 Multi 1 CRS Performance Monitoring Values, continued

MONTYPE

MAX 15 MIN.
THRESHOLD

COMMENTS

AAL 1 LAYER

Stuffing Cells

9900

Indicates a count of AIS cells inserted into the data stream for stuffing
purposes in a 15-minute interval.

Congestion Lost
Cells

32 BITS

Indicates a count of cells discarded in a 15-minute interval.

AAL1
Sequence Errors

31 BITS

A count of “Out of Sequence” transitions in a 15-minute interval.

Lost Cells

31 BITS

A count of cells lost in a 15-minute interval.

Buffer
Overflow

900

Indicates a count of buffers that have overflowed in a 15-minute period.

Buffer
Underflow

900

Indicates a count of buffers that have under flowed in a 15-minute period.

ATM / TC

Suspect

1

Suspect defines counts that are suspected to have errors but may have been
reset to zero by a user during the reporting period.

Supp

3695745

Suppressed intervals flag indicates that there was no data to report for an
interval (all counts are zero). This saves the user from having to look at a
bunch of zeros and also reduces the size of the PM data files.

Hdr Errs

3695745

Sets a count of errors in the ATM header that the system can incur before
notifying the system administrator.

OAM Rcvd

3695745

A count of Operation, Administration, and Maintenance cells received in a
15-minute period, used for testing purposes such as loopback request
codes.

In Cells

3695745

A total count of all of the cells that have been received on an interface.
This is for user information and not configurable.

Out Cells

3695745

A total count of all of the cells that have been transmitted out from an
interface. This is for user information and is not configurable.

HEC Viols

3695745

Sets a count of Header Error Checksum violations that the system can
incur before notifying the system administrator.

OCDs

900

Sets a count of Out of Cell Delineation anomalies that the system can incur
before notifying the system administrator.

*BPV (Bi-Polar Violation) = Occurrence of pulses of same polarity as the previous pulse except
as part of the B8ZS substitution code.

*ExZ (Excessive Zero) = Occurrence of any zero string greater than “N” contiguous zeros,
where “N” = 7 for B8ZS or 15 for AMI (Alternate Mark Inversion).

Advertising