Dlp-726, Page 3 of 4 – ADC Release 3.1 User Manual

Page 165

Advertising
background image

1152700

Issue 1

February 2001

Section 2 Operation and Maintenance

Page 2-145

2000, ADC Telecommunications, Inc.

DLP-726

Page 3 of 4

Cellworx Vision: Performance Monitoring Data NE 2

Card Type

Refresh All

X

155 MM CRS

Slot-Port

Interval

Suspect Supp

ESs

SESs

CVs

UASs

FE ESs

FE SESs

FE CVs

S12-P2

00:00 - 00:15

0

0

0

0

0

0

0

0

900

Configure Thresholds

Close

Refresh

SONET Path

SONET Line

SONET Section

Only non-zero selected intervals are displayed.

13556-B

Reset Selected

Clear Selected

Figure 726-2. Performance Monitoring Data – SONET Port Window

Cellworx Vision: PM Threshold Configuration SONET Path Layer

Card Type

X

622 Ring

Slot-Port

ESs

SESs

CVs

UASs

FE ESs

FE SESs

FE CVs

FE UAS

S17-P1

3

75

10

60

3

60

0

0

Close

Apply

13552-B

Figure 726-3. 622 Ring Card SONET Path PM Threshold Configuration Screen

Table 726-1. SONET PM Values

MONITOR

TYPE

MAX 15-MIN
THRESHOLD

COMMENTS

SECTION

CV

16383

Code Violation, a count of Bit Interleaved Parity (BIP) errors detected at the Section
layer using the B1 byte in the incoming SONET signal

ES

900

Errored Seconds, number of seconds in which at least one Section layer Bit
Interleaved Parity (BIP), Loss Of Signal (LOS), or Severely Errored Frame (SEF)
was detected

SEFS

900

Severely Errored Frame Seconds, a count of seconds that four consecutive incoming
section frames are errored

SES

900

Severely Errored Seconds, a count of seconds in which a set number of Section BIP
errors, LOS, or SEF were detected

(continued)