Section 2 Operation and Maintenance

Page 2-436
© 2000, ADC Telecommunications, Inc.

DLP-796

Page 3 of 3

Table 796-1. 622 Card Status Definitions, continued

ITEM

STATUS

DEFINITION

ACTION

Path Status

(continued)

STS AIS

STS RDI

Unequipped

SignalLabel
Mismatch

STS Alarm Indication Signal.
Remote end transmitting AIS due
to loss of payload for path.

STS Remote Defect Indication.
Remote end is receiving a
defective signal.

This time slot is not utilized
(unequipped).

Type of signal does not match
overhead description.

Check remote transmitting end’s
input signal.

Check local end transmitter and
connections.

Create a connection if needed on this
available timeslot per DLP-708.

Check VP connection for
provisioning errors per DLP-710.

Sync Status

PRC
PRS
SEC
SSU
ST1
STU

ST2
ST3
SMC
DUS

SDH Primary Reference Clock
Primary Reference Source
SDH Equipment Clock Traceable
SDH Sync Supply Unit Traceable
Stratum 1 level source
Synchronized Traceability
Unknown
Stratum 2 level source
Stratum 3 level source
SONET Minimum level Clock
Reference cannot be used for
source

Timing reference reliability levels. If
sync status does not meet required
level, check source and inputs.
Provide the required clock source
and change configuration settings for
the card per DLP-749.

No action required.

Received Path
Trace Msg

(SM card
only)

User Defined

No Path
Trace

Path trace is a 64-character string
assigned to a path between nodes
in either direction identifying the
transmitting node.

No action required. If message states
no path trace, one may be
provisioned, for SM cards only, at
either or both of the two adjacent
nodes (clockwise and counter-
clockwise node). Refer to DLP-797.

Protection
State

Not Protected

Enabled

Manual
switch

Forced
Switch

Lockout

Unknown

Not Protected

Protection is available for selected
card but is not active.

User has manually switched the
card to protection.

User has forced card to protection.

Card cannot switch to protection.
It has been locked out by
command or switch count.

Protection status information is
not available to the shelf
controller.

If equipped, set up a protection
group and provision card for
protection per DLP-765.

No action necessary.

If required, switch the card back per
DLP-771.

If required, release forced switch per
DLP-771.

If required, release manual lock-out
per DLP-771.

Wait a few minutes and update
screen. May need to reset SC, refer
to DLP-773.