Section 2 Operation and Maintenance

Page 2-236
© 2000, ADC Telecommunications, Inc.

DLP-751

Page 3 of 3

Table 751-1. 622 RIC Card Configuration Options, continued

SELECTION

DEFAULT

OPTIONS

DEFINITION

Signal
Degrade BER
Threshold

5

5 through 9

Defines the number of bit errors the port can incur
before a signal degrade occurs and generates an
alarm message and probably protection switch.

Medium Type

SONET

SONET

SDH

Not configurable on RIC. This is determined by the
dipswitch on the SC EIM, which sets the shelf type.
Can be SONET, Synchronous Optical Network, US,
or Synchronous Digital Hierarchy, European
standard for transporting data over fiber.

Loopback
towards

None

None

Terminal

Facility

No loopback activated on this card.

Sends cells back to the cellbus and back out to the
ring. No changes are made to the path layer data.

Loops the incoming signal back to the CPE and
generates AIS to the cellbus.

Line Coding

NRZ

Not configurable by user.

Line Type

Card
Dependant

SonetOther

sonetShortSingle
Mode

sonetLongSingle
Mode

sonetMultiMode

Not configurable by user, dependant on card type
inserted.

Transmit Path
Trace

(example)

NE1_Slot17_
Port1 (OC12)

Card position dependent. This is assigned by the
system according to the NE and slot it is equipped in.

1