download status for the cards. All cards should say, "Loaded". If not, wait a few more minutes

and click Refresh again.

55. Once all cards are loaded with the release 3.0 bootrom, each card in the shelf must be hard

reset to load the new bootrom.

Note: Hard resetting a card is traffic affecting. When you upgrade the flash bootrom on
each card, you may want to take this into consideration. To minimize traffic loss, you
should consider using 1+1 or 1:N protection and resetting the cards such that a card is
always active. This will take longer, but you will avoid traffic loss.

56. Repeat steps 46 through 49 for each NE in the ring.

57. Following hard reset of all cards in all NEs in the ring, software upgrade is complete.

58. Following software upgrade, the user should manually delete the 2.1.0.25 AIC flash image

that was installed previously. This will remove the possibility of inadvertently selecting this
image in a Release 3.0 system:

rm –f /cellworx/flashImage/aic/bootrom_Ver2/bootrom.2.1.0.25

Stop! You have completed this procedure.