Table 753-2. ATM Interface Configuration Options, Continued

SELECTION

DEFAULT

OPTIONS

DEFINITIONS

Interface Type

UNI

UNI
NNI

Specifies interface type as User to Network
Interface or Network to Network Interface.

CAC Formula

PCR

PCR
SCR

Specifies Peak Cell Rate or Sustained Cell Rate
for Connection Admission Control calculations.

Policing

Off

On or Off

User sets whether traffic will be policed for
Quality Of Service (QOS).

Cell Scrambling

Off

On or Off

User sets whether traffic will be scrambled.

Over Subscription Rate

100

User sets depending on traffic contract.

Max Active VPI/VCI
Bits

0

0-12

Sets maximum number of bits allowed to select
VCs from.

Max number of VPCs

1

1 to 2048

Sets the maximum number of VPCs that may be
utilized from this port.

Max number of VCCs

0

0 to 8192

Sets the maximum number of VCCs that may be
utilized from this port.

Cellworx Vision: ATM Interface

Apply

Card View

Refresh

Close

X

Node Name: Cellworx1

Node Id: 1

Location: 5th Street

Slot Number: 9

Card : T3 CRS

Port Number: 1

Interface Name:

Slot9_Port1 DS3

Loopback Location Code:

Recording Interface ID:

1111111111111111

0000000000000000

Provisioned Endpoints:

Number of VPCs: 0

Number of VCCs: 0

Interface Type: CAC Formula:

UNI

NNI

PCR Based

SCR Based

Policing

Cell Scrambling

Over Subscription Rate (%):

(100-10

100

VP/VC Allocation:

Max Active VPI Bits:

0

0

1

2

3

4

5

6

7

8

Max Active VCI Bits:

0

Max Number of VPCs:

Max Number of VCCs:

(1-2048)

(0-256)

Error Log:

9

10

1

0

2048

0

13432-A

Figure 753-2. T3 CRS ATM Interface Screen