This group of parameters contains values that can be helpful in explaining the operation of
the drive. Drive status, direction, control and alarm conditions as well as drive ratings are
included.

Diagnostics

[Drive Status]

This parameter displays the actual
operating condition in binary format.

Bits 0-7 are displayed on lower half
of line 2 on HIM display, while, bits
8-15 are displayed on the upper half
of line 2.

With drive software versions above
2.00 and a Series A (version 3.0) or
Series B HIM, a Status description
(bit ENUM) is displayed on line 1.

Parameter Number

59

Parameter Type

Read Only

Enabled

Running

Command Direction

Actual Direction

Accelerating

Decelerating

Faulted

At Speed

Bit 15

Bit 13 Bit 12 Bit 11 Bit 10 Bit 9

Bit 8

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

Alarm

0 = Reverse

1 = Forward

0 = Reverse

1 = Forward

Reference

ID

Local

Adapter ID

Reference

15 14 13 12

Freq Select 1

0

0

0

0

Preset Freq 1

0

0

0

1

Preset Freq 2

0

0

1

0

Preset Freq 3

0

0

1

1

Preset Freq 4

0

1

0

0

Preset Freq 5

0

1

0

1

Preset Freq 6

0

1

1

0

Preset Freq 7

0

1

1

1

Freq Select 2

1

0

0

0

Adapter 1

1

0

0

1

Adapter 2

1

0

1

0

Adapter 3

1

0

1

1

Adapter 4

1

1

0

0

Adapter 5

1

1

0

1

Adapter 6

1

1

1

0

Jog Frequency 1

1

1

1

Local

11 10 9

TB3

0

0

0

1

0

0

1

2

0

1

0

3

0

1

1

4

1

0

0

5

1

0

1

6

1

1

0

Unused

1

1

1

Bit 14

[2nd Drive Sts] –Frm. 4.01 & later

This parameter displays the actual operating
condition in binary format.

Bits 0-7 are displayed on lower half of line 2
on HIM display, while, bits 8-15 are displayed
on the upper half of line 2.

With drive software versions above 4.01 and
a Series A (version 3.0) or Series B HIM, a
Status description (bit ENUM) is displayed on
line 1.

Parameter Number

236

Parameter Type

Read Only

At Freq

At Current

At Torque

Current Lmt

Mtr Overload

Line Loss

Drive Ready

Forward Run

Bit 15

Bit 13 Bit 12 Bit 11 Bit 10 Bit 9

Bit 8

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

Drive Power

Bit 14

Reverse Run

Braking

Auto Reset

Economize

Unused

[Drive Alarm]

This parameter displays which
alarm condition is present when bit
6 of [Drive Status] is high
(set to 1). Refer to Chapter 6 for
further alarm information.

With drive software versions above
2.00 and a Series A (version 3.0) or
Series B HIM, a Status description
(bit ENUM) is displayed on line 1.

Parameter Number

60

Parameter Type

Read Only

Bus Charging

Regenerating Current Limit

Regenerating Voltage Limit

Line Loss In Progress

Motor Stalled

Ground Warning

Bit 15

Bit 13 Bit 12 Bit 11 Bit 10 Bit 9

Bit 8

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

Mtr Overload

Unused

Bit 14

Hardware Current Limit

Motoring Current Limit

Motor OL Trip

Auto Reset

Voltage Check

Heatsink Temp

Auxiliary Input

4-20 mA Loss