Rockwell Automation 1336S Plus FRN 1.xx-5.xx User Manual

Page 118

Advertising
background image

5–40

Programming

[Reference Mask]

This parameter controls which adapters can select
an alternate reference; [Frequency Sel 1],
[Frequency Sel 2] or preset speeds.

Parameter Number

97

Parameter Type

Read and Write

Factory Default

01111111

Units

Display Drive

“0” 0

Deny Control

“1” 1

Permit Control

[Accel Mask]

This parameter controls which adapters can select
[Accel Time 1] and [Accel Time 2].

Parameter Number

98

Parameter Type

Read and Write

Factory Default

01111111

Units

Display Drive

“0” 0

Deny Control

“1” 1

Permit Control

[Decel Mask]

This parameter controls which adapters can select
[Decel Time 1] and [Decel Time 2]

Parameter Number

99

Parameter Type

Read and Write

Factory Default

01111111

Units

Display Drive

“0” 0

Deny Control

“1” 1

Permit Control

[Fault Mask]

This parameter controls which adapters can reset a
fault.

Parameter Number

100

Parameter Type

Read and Write

Factory Default

01111111

Units

Display Drive

“0” 0

Deny Control

“1” 1

Permit Control

[MOP Mask]

This parameter controls which adapters can issue
MOP commands to the drive.

Parameter Number

101

Parameter Type

Read and Write

Factory Default

01111111

Units

Display Drive

“0” 0

Deny Control

“1” 1

Permit Control

[Logic Mask]

Determines which adapters can control the drive. If
the bit for an adapter is set to “0,” the adapter will
have no control functions except for stop. In addi-
tion, the adapter can be removed from the drive
while power is applied without causing a serial fault.

Parameter Number

92

Parameter Type

Read and Write

Factory Default

01111111

Units

Display Drive

“0” 0

Deny Control

“1” 1

Permit Control

[Local Mask]

This parameter controls which adapters are allowed
to take exclusive control of drive logic commands
(except stop). Exclusive “local” control can only be
taken while the drive is stopped.

Parameter Number

93

Parameter Type

Read and Write

Factory Default

01111111

Units

Display Drive

“0” 0

Deny Control

“1” 1

Permit Control

Masks