Full custom fixed fan select 1 & 2/no boost, Flux amps ref] – firmware 4.01 & later – Rockwell Automation 1336S Plus FRN 1.xx-5.xx User Manual

Page 129

Advertising
background image

5–51

Programming

This group of parameters defines basic motor control and is only available with firmware
version 4.01 and up.

Motor Control

[Control Select] – Firmware 4.01 & later

Selects the motor control method for the drive. The
default setting provides full stator flux control that is
suitable for most applications.

Additional selections are offered to optimally tune
performance:

Two volts/Hertz modes are available; one using
simple voltage boost and one for complete
configurability. These may be required for special
motors or unmatched multi-motor installations.

The Economize mode offers all the advantages of
stator flux control plus the added feature of an
“auto-economizer.” If a motor remains lightly
loaded for a specified period of time, the drive will
attempt to reduce output voltage (and therefore
output kW) in order to reduce the energy
(operating) costs of the lightly loaded motor.

Parameter Number

9

Parameter Type

Read and Write

Factory Default

“Sens Vector”

Units

Display Drive

“Economize” 0

Stator Flux control with Economize

“Sens Vector” 1

Stator Flux control

“Fixed Boost” 2

V/Hz w/programmed accel/run boost

“Full Custom” 3

V/Hz with full configuration

Base

Voltage

0

0

Base Frequency

100%

50%

42%
35%

100%

50%

Fan 1

Fan 2

No Boost

Voltage

0

0

Frequency

Motor Rated

Maximum

Start Boost

Break Voltage
Break Frequency

Maximum

Base Voltage

Base Frequency

Maximum Voltage
Maximum Frequency

Motor Rated

Full Custom

Fixed

Fan Select 1 & 2/No Boost

Voltage

0

0

Frequency

Run Boost

Start Boost

B

A

Base Voltage

Base Frequency

[Flux Amps Ref] – Firmware 4.01 & later

Used in Sensorless Vector mode only – Sets the
value of amps required to maintain full motor flux. If
set to zero, the drive will use an internal value based
on [Motor NP Amps] and drive kW (HP). Refer to
Chapter 4 for setup information.

Parameter Number

192

Parameter Type

Read and Write

Display Units / Drive Units

0.1 Amp / 4096 = Drive Rated Amps

Factory Default

0.0 Amps

Minimum Value

0.0 Amps

Maximum Value

75.0% of Drive VT Rated Amps

Advertising