1–3

Information and Precautions

1336S

First Position

Bulletin Number

BR

Second Position

Voltage

Letter

Voltages

AQ

200-240V AC or
310V DC

BR

380-480VAC or
513-620V DC

CW

500-600V AC or
775V DC

A

200-240V AC

B

380-480V AC

BP

380-480V AC
(F Frame)

BX

Special Rating

C

500-600V AC

Q

310V DC

R

513-620V DC

RX

Special Rating

W

775V DC

F30

Third Position

Nominal HP Rating

Code

kW (HP)

F05

0.37 (0.5)

F07

0.56 (0.75)

F10

0.75 (1)

F15

1.2 (1.5)

F20

1.5 (2)

F30

2.2 (3)

F50

3.7 (5)

F75

5.5 (7.5)

F100 7.5 (10)

007

5.5 (7.5)

010

7.5 (10)

015

11 (15)

020

15 (20)

025

18.5 (25)

030

22 (30)

040

30 (40)

050

37 (50)

060

45 (60)

075

56 (75)

100

75 (100)

125

93 (125)

150

112 (150)

200

149 (200)

250

187 (250)

1

300

224 (300)

1

350

261 (350)

1

400

298 (400)

1

450

336 (450)

1

500

373 (500)

1

600

448 (600)

1

AA

Fourth Position

Enclosure Type

Code

Type

AA

IP 20 (NEMA 1)

AE

IP 20 (NEMA 1)/
EMC
0.37-45 kW
(0.5-60 HP) only

AF

IP 65 (NEMA 4)

2

AJ

IP 54 (NEMA 12)

2

AN

IP 00 (Open)

EN

Fifth Position

Language

Code

Language

EN3 English/English V3.04
EN4 English/English V4.xx

FR3 English/French V3.04
FR4 English/French V4.xx

DE3 English/German V3.04
DE4 English/German V4.xx

IT3

English/Italian V3.04

IT4

English/Italian V4.xx

ES3 English/Spanish V3.04
ES4 English/Spanish V4.xx

MODS

Sixth Position

Options

Code

Description

Human Interface Module, IP 20 (Type 1)

HAB Blank – No Functionality
HAP Programmer Only
HA1 Programmer/Controller w/Analog Pot
HA2 Programmer/Controller w/Digital Pot

Human Interface Module, IP 65/54 (Type 4/12)

HJP Programmer Only
HJ2

Programmer/Controller w/Digital Pot

Code

Description

Communication Options

GM1 Single Point Remote I/O
GM2 RS–232/422/485, DF1 & DH485
GM5 DeviceNet

Control Interface Options

L4

TTL Contact

L4E

TTL Contact & Encoder Feedback

L5

24V AC/DC

L5E

24V AC/DC & Encoder Feedback

L6

115V AC

L6E

115V AC & Encoder Feedback

or

1

G Frame Drives in enclosed construction are supplied through the Configured Drives Program.

2

D through G Frame drives in IP 65 (NEMA Type 4) and IP 54 (NEMA Type 12) configurations are supplied through the Configured Drives Program.