Rockwell Automation 1336S Plus FRN 1.xx-5.xx User Manual

Page 27

Advertising
background image

2–17

Installation/Wiring

Table 2.F
Maximum Motor Cable Length Restrictions in meters (feet) – 500V-600V Drives

4

No External Devices

w/ 1204-TFB2 Terminator

w/ 1204-TFA1 Terminator

Reactor at Drive

2

Motor

Motor

Motor

Motor

A

B

1329R/L
Motors

6

A

B

1600V or
1329R/L

6

A

B

1600V or
1329R/L

A

B

1600V or
1329R/L

Drive
Frame

Drive kW
(HP)

Motor kW
(HP)

Any
Cable

Any
Cable

Any
Cable

Any
Cable

Any
Cable

Any
Cable

Any
Cable

Any
Cable

Any
Cable

Any
Cable

Any
Cable

Any
Cable

A4

0.75 (1)

0.75 (1)

NR

NR

182.9
(600)

NR

182.9
(600)

335.3
(1100)

NR

61.0
(200)

182.9
(600)

0.37 (0.5)

NR

NR

182.9
(600)

NR

182.9
(600)

335.3
(1100)

NR

61.0
(200)

182.9
(600)

1.5 (2)

1.5 (2)

NR

NR

182.9
(600)

NR

182.9
(600)

335.3
(1100)

NR

61.0
(200)

182.9
(600)

1.2 (1.5)

NR

NR

182.9
(600)

NR

182.9
(600)

335.3
(1100)

NR

61.0
(200)

182.9
(600)

0.75 (1)

NR

NR

182.9
(600)

NR

182.9
(600)

335.3
(1100)

NR

61.0
(200)

182.9
(600)

0.37 (0.5)

NR

NR

182.9
(600)

NR

182.9
(600)

335.3
(1100)

NR

61.0
(200)

182.9
(600)

2.2 (3)

2.2 (3)

NR

NR

182.9
(600)

NR

182.9
(600)

335.3
(1100)

NR

61.0
(200)

182.9
(600)

1.5 (2)

NR

NR

182.9
(600)

NR

182.9
(600)

335.3
(1100)

NR

61.0
(200)

182.9
(600)

Not

Recommended

0.75 (1)

NR

NR

182.9
(600)

NR

182.9
(600)

335.3
(1100)

NR

61.0
(200)

182.9
(600)

Recommended

0.37 (0.5)

NR

NR

182.9
(600)

NR

182.9
(600)

335.3
(1100)

NR

61.0
(200)

182.9
(600)

3.7 (5)

3.7 (5)

NR

NR

182.9
(600)

NR

182.9
(600)

335.3
(1100)

NR

61.0
(200)

182.9
(600)

2.2 (3)

NR

NR

182.9
(600)

NR

182.9
(600)

335.3
(1100)

NR

61.0
(200)

182.9
(600)

1.5 (2)

NR

NR

182.9
(600)

NR

182.9
(600)

335.3
(1100)

NR

61.0
(200)

182.9
(600)

0.75 (1)

NR

NR

182.9
(600)

NR

182.9
(600)

335.3
(1100)

NR

61.0
(200)

182.9
(600)

0.37 (0.5)

NR

NR

182.9
(600)

NR

182.9
(600)

335.3
(1100)

NR

61.0
(200)

182.9
(600)

B

5.5-15
(7.5-20)

5.5-15
(7.5-20)

NR

9.1
(30)

182.9
(600)

91.4
(300)

182.9
(600)

5

NR

61.0
(200)

5

30.5
(100)

91.4
(300)

182.9
(600)

C

18.5-45
(25-60)

18.5-45
(25-60)

NR

9.1
(30)

182.9
(600)

91.4
(300)

182.9
(600)

5

NR

61.0
(200)

5

30.5
(100)

91.4
(300)

182.9
(600)

D

56-93
(75-125)

56-93
(75-125)

NR

9.1
(30)

182.9
(600))

91.4
(300)

182.9
(600)

5

NR

61.0
(200)

5

61.0
(200)

91.4
(300)

182.9
(600)

E

112-224
(150-X300)

112-224
(150-X300)

NR

9.1
(30)

182.9
(600)

91.4
(300)

182.9
(600)

5

NR

61.0
(200)

5

182.9
(600)

182.9
(600)

182.9
(600)

F

187-336
(250-450)

187-336
(250-450)

NR

9.1
(30)

182.9
(600)

91.4
(300)

182.9
(600)

5

NR

61.0
(200)

5

182.9
(600)

182.9
(600)

182.9
(600)

G

224-448
(300-600)

224-448
(300-600)

NR

9.1
(30)

182.9
(600)

91.4
(300)

182.9
(600)

5

NR

61.0
(200)

5

182.9
(600)

182.9
(600)

182.9
(600)

NR = Not Recommended

1

Values shown are for 480V nominal input voltage and drive carrier frequency of 2 kHz. Consult factory regarding operation at carrier frequencies above 2 kHz.
Multiply values by 0.85 for high line conditions. For input voltages of 380, 400 or 415V AC, multiply the table values by 1.25, 1.20 or 1.15, respectively.

2

A 3% reactor reduces motor and cable stress but may cause a degradation of motor waveform quality. Reactors must have a turn–turn insulation rating of 2100
volts or higher.

3

Includes wire in conduit.

4

Values shown are for nominal input voltage and drive carrier frequency of 2 kHz. Consult factory regarding operation at carrier frequencies above 2 kHz. Multiply
values by 0.85 for high line conditions.

5

Information not available at time of printing.

6

These distances require new 1329R or 1329L motors. New motors at 600V are rated at approximately 1850V insulation value. These distances are only valid with
firmware version 4.03 or higher.

7

These distance restrictions are due to charging of cable capacitance and may vary from application to application. These distances are only valid with firmware
version 3.04 or higher.