SNMP Commands

FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Plasma-ARC

2+3\new_system_mifs_ARC2_latest\SNMP.fm

D E L L C O N F ID E N T IA L – P R E L IM I N A RY 4 / 3 /1 4 - FO R P R O O F O N LY

User Guidelines

The command

snmp-server enable traps

enables all traps including failure

traps. Therefore, if that command is enabled (it is enabled by default), this

command is not necessary.

Example

The following example disables all SNMP traps and enables only failed

authentication traps.

console(config)# no snmp-server enable traps

console(config)# snmp-server trap authentication

snmp-server contact

Use the snmp-server contact Global Configuration mode command to set the

value of the system contact (sysContact) string. Use the no form of the

command to remove the system contact information.

Syntax

snmp-server contact

text

no snmp-server contact

Parameters

text—Specifies system contact information. (Length: 1–160 characters)

Default Configuration

N/A

Command Mode

Global Configuration mode

Example

The following example sets the system contact information to

Technical_Support.

console(config)# snmp-server contact Technical_Support