Port Naming Convention

The following describes the types of ports and port naming conventions of

the ports on the R1-2401 device.

Types of Ports

The following ports are found on the R1-2401 switch:

24 x 1 Gigabit/s Ethernet Ports. These consist of:

8 external ports—Connected to network (visible when the switch is in

the chassis)

16 internal ports—Connected to blade servers (not visible when the

switch is in the chassis)

• Single Internal Out-of-Band port

The switch supports an Out-of-Band (OOB) port that is connected to the

management network of the chassis.

Port Naming Convention

There are 5 groups of ports, numbered 0-4. Group 0 represents the external

ports and groups 1-4 represents the internal ports that are connected to blade

servers 1-4.

External/Internal Ports

The following naming convention is used for internal and external ports:

gigabitethernet group/port_number or gi group/port_number

The following table maps the hardware network port numbers to the software

interface port numbers and describe how they are referred to in the CLI/GUI

Port Type and Number

Software Port Naming Convention in CLI/WEB

External ports 1-8

gi0/1.... gi0/8

Internal ports 1-4

gi1/1.... gi1/4

Internal ports 5-8

gi2/1.... gi2/4

Internal ports 9-12

gi3/1.... gi3/4

Internal ports 13-16

gi4/1.... gi4/4

Out-of-Band port

oob