Remote Network Monitoring (RMON) Commands

FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Plasma-ARC

2+3\new_system_mifs_ARC2_latest\RMON.fm

D E L L C O N F ID E N T IA L – P R E L IM I N A RY 4 / 3 /1 4 - FO R P R O O F O N LY

falling —Specifies that if the first sample (after this entry becomes

valid) is less than or equal to falling-threshold, a single falling alarm is

generated.

owner

name

—Specifies the name of the person who configured this alarm.

(Valid string)

Default Configuration

The default method type is absolute.
The default startup direction is rising-falling.
If the owner name is not specified, it defaults to an empty string.

Command Mode

Global Configuration mode

Example

The following example configures an alarm with index 1000, MIB object ID

D-Link, sampling interval 360000 seconds (100 hours), rising threshold value

1000000, falling threshold value 1000000, rising threshold event index 10,

falling threshold event index 10, absolute method type and rising-falling

alarm.

console(config)# rmon alarm 1000 1.3.6.1.2.1.2.2.1.10.1 360000

1000000 1000000 10 20

show rmon alarm-table

Use the show rmon alarm-table Privileged EXEC mode command to display a

summary of the alarms table.

Syntax

show rmon alarm-table

Command Mode