FT-10 Smart Process Indicator, Technical Manual, Rev. 1.0, January 2014

PROFIBUS Connector pin configuration (DB9F)

Pin

Signal

Description

1

-

-

2

-

-

3

B Line

Positive RxD / TxD, RS-485 level

4

RTS

Request to send

5

GND Bus

Ground (isolated)

6

+5V Bus Output

+5V termination power (isolated)

7

-

-

8

A Line

Negative RxD / TxD, RS-485 level

9

-

-

Housing

Cable Shield

Ground

4.3.7 Profinet Connection (only FT-10 PN )

Profinet connection is done as indicated in Figure 4.8.


Figure 4.8 - FT-10 PN serial interface connections

PROFINET Connector pin configuration (RJ45)

Pin

Signal

DIR

Description

1

TX+

Out

Differential Ethernet transmit data +

2

TX−

Out

Differential Ethernet transmit data −

3

RX+

In

Differential Ethernet receive data +

6

RX−

In

Differential Ethernet receive data −

4

Not used

Terminated

5

Not used

Terminated

7

Not used

Terminated

8

Not used

Terminated

Shield

Chasis ground


The HUB connection cabling will be a direct connection as shown in Figure 4.9:

Figure 4.9 - HUB connection




The PC connection cabling will be done via cross cable as shown below. IP address blocks and gateway
address of FT-10 and PC should be the same in cross connection.