FT-10 Smart Process Indicator, Technical Manual, Rev. 1.0, January 2014

Page 73 of 82

12.2 CANopen Data Structure

FT-10 CO Output to PLC Input

Bitwise of a Ulong:

Unsigned
Long
(Only
read)

D63 D62 D61 D60 D59 D58 D57 D56 D55 D54 D53 D52 D51 D50 D49 D48

D47 D46 D45 D44 D43 D42 D41 D40 D39 D38 D37 D36 D35 D34 D33 D32

D31 D30 D29 D28 D27 D26 D25 D24 D23 D22 D21 D20 D19 D18 D17 D16

D15 D14 D13 D12 D11 D10 D9

D8

D7

D6

D5

D4

D3

D2

D1

D0


TxPDO 1
(T_UL1)

Out
5

Out
4

Out
3

Out
2

Out
1

In
4

In
3

In
2

In
1

Error codes of FT-10 CO

Not in use

Zero

range

Gross

Net

MD

Read command response

Cmd
Flg

By default, Indicated weight value is represented.
To represent other weight or calibration status, refer to D33…D37.


FT-10 CO Output to PLC Input TxPDO 1 (T_UL1)

Bit Number

TxPDO 1 (T_UL1) Description

D63 … D56

Outputs

Output bit status ( Active = 1 )

D55 … D48

Inputs

Input bit status ( Active = 1 )

D47 … D44

Error Codes of
FT-10 CO

Bin

Dec

0000

0

No error found

0001

1

ADC out

0010

2

ADC over

0011

3

ADC under

0100

4

System Error

0101

5

In programming mode

0110

6

Low/High Voltage Error

D43 … D41

Not in use

D40

Zero Range

0

Weight is in zero range

1

Weight is out of zero range

D39

Indication

0

Gross

1

Net

D38

MD

– Motion

Detection

0

Stable

1

Dynamic




D37 … D33







D37 … D33



Read
Command
Response






Read
Command
Response

00000

0

Indicated weight

00001

1

Gross weight

00010

2

Tare weight

00011

3

Calibration Status (Refer to Table 12.1)

00100
01110

4
14

Not used

01111

15

Set Point-1 Low

10000

16

Set Point-1 High

10001

17

Set Point-2 Low

10010

18

Set Point-2 High

10011

19

Set Point-3 Low

10100

20

Set Point-3 High

10101

21

Set Point-4 Low

10110

22

Set Point-4 High

10111

23

Set Point-5 Low