Flintec FT-10xx User Manual

Page 55

Advertising
background image

FT-10 Smart Process Indicator, Technical Manual, Rev. 1.0, January 2014

FT-10 PB Output to PLC Input 2

nd

Dword

Bit Number

2

nd

Dword Description

D31 … D24

Outputs

Output bit status ( Active = 1 )

D23 … D16

Inputs

Input bit status ( Active = 1 )

D15 … D12

Error Codes
of FT-10 PB

Bin

Dec

0000

0

No error found

0001

1

ADC out

0010

2

ADC over

0011

3

ADC under

0100

4

System Error

0101

5

In programming mode

0110

6

Low/High Voltage Error

D11 … D9

Not in use

D8

Zero Range

0

Weight is in zero range

1

Weight is out of zero range

D7

Indication

0

Gross

1

Net

D6

MD

– Motion

Detection

0

Stable

1

Dynamic




D5 … D1





D5 … D1



Read
Command
Response





Read
Command
Response

(continuation
of previous
page)

00000

0

Indicated weight

00001

1

Gross weight

00010

2

Tare weight

00011

3

Calibration Status

00100
01110

4
14

Not used

01111

15

Set Point-1 Low

10000

16

Set Point-1 High

10001

17

Set Point-2 Low

10010

18

Set Point-2 High

10011

19

Set Point-3 Low

10100

20

Set Point-3 High

10101

21

Set Point-4 Low

10110

22

Set Point-4 High

10111

23

Set Point-5 Low

11000

24

Set Point-5 High

11111

31

Use the Expanded Command list ( Refer to Table

9.1

)

D0

CMD Flag

Toggles

The command is applied successfully