3 specifications – Flintec FT-10xx User Manual

Page 8

Advertising
background image

FT-10 Smart Process Indicator, Technical Manual, Rev. 1.0, January 2014

3.3 Specifications:

Common Specifications

A/D Converter

A/D converter type

24 bit Delta-Sigma radiometric with integral analog and digital filters

Conversion rate

Up to 1600 measurement values per second

Input sensitivity

0.1 μV/d (non approved)

Analog input range

0 mV to +18 mV ( unipolar ) ;

- 18 mV to +18 mV ( bipolar )

Internal resolution

up to 16 000 000

External Resolution

Display resolution

up to 999 999 increment

Scale Calibration and Functions

Calibration

Calibration is performed with or without test weights ( eCal )

Digital filter

10 steps programmable adaptive filter

Weighing functions

Taring, zeroing, auto zero tracking, motion detection, auto zero at power up, net
indication at power on, increased resolution

Linearity

Within 0.0015% FS,

2 ppm/°C

Load cells

Excitation

5 VDC max. 300 mA

Number of load cells

Up to 8 load cells 350 Ω or 18 load cells 1100 Ω in parallel

Connection

4- or 6-wire technique.
Cable length: maximum 250 m/mm² for 6-wire connection

Digital Inputs and Outputs

Digital Inputs

2 optoisolated digital inputs at FT-10 AN,
4 optoisolated digital inputs at FT-10, FT-10 MB, FT-10 PB, FT-10 PN, FT-10
EN, FT-10 CO;
12 to 28 VDC, 10mA

Digital Outputs

4 free relay contact at FT-10 AN,
5 free relay contact at FT-10, FT-10 MB, FT-10 PB, FT-10 PN, FT-10 EN, FT-10
CO
250 VAC or 30 VDC , 1A

Power consumption

12 to 28 VDC max. 300 mA

Electronic calibration (eCal) over field bus

-

-

-

X

X

X

X

X

X

Zero and Span calibrations over field bus

-

-

-

X

X

X

X

X

X

Zero adjustment

X

X

X

X

X

X

X

X

X

Span adjustment with test weights

X

X

X

X

X

X

X

X

X

Span adjustment for filled tanks

X

X

X

X

X

X

X

X

X

3 point calibration ( linearity correction )

X

X

X

X

X

X

X

X

X

Programming by IndFace PC software

X

X

X

X

X

X

X

X

X

8 load cells 350 Ω or 18 load cells 1100 Ω

X

X

X

X

X

X

X

X

X

12 to 28 VDC power supply range

X

X

X

X

X

X

X

X

X

Advertising