FT-10 Smart Process Indicator, Technical Manual, Rev. 1.0, January 2014

Page 71 of 82

12. CAN

OPEN

(

ONLY

FT-10

CO

)

After programming CANopen related parameters of the FT-10 PB indicator, you can communicate with the
instrument. EDS file is available on CD which is supplied together with the instrument.
Automatically detected and supported baud rates are 10 kbps, 50 kbps, 100 kbps, 125 kbps, 250 kbps, 500
kbps, 800 kbps, 1 Mbps, Autobaud (default).

[07-] CANopen

This sub-block includes the parameters related with the CANopen interfaces of FT-10 indicator.

[070 0] Data Format

0 : Signed 32 bit integer, no decimal point implied
1 : 32 bit float, decimal point implied

[071 000] Rack Address

The CANopen rack address of FT-10 will be entered via keypad between 001 to 126.


There are 2 LED’s near the CANopen connector which are;



Run LED

State

Indication

Comment

Off

Not online / No power

Check power and cable

Green

On-line, data exchange

-

Green, blinking

On-line, initializing

-

Green, single flash

Stopped

Check hardware damages

Green, flickering

Auto baudrate detection in progress

-

Red

CANopen configuration error

Check EDS file


Error LED

State

Indication

Comment

Off

-

No power or CANopen module is in
initialization state

Red, single flash

Warning limit reached

A bus error counter reached or
exceeded its warning level

Red, flickering

LSS

LSS services in progress

Red, double flash

Error count event

A guard- (NMT-Slave or NMT-
master) or heartbeat event
(Heartbeat consumer) has occurred.

Red

Bus off (Fatal Event)

Bus off.

1

Run LED

2

Error LED

3

CANopen interface

Advertising