Flintec FT-10xx User Manual
Page 42
FT-10 Smart Process Indicator, Technical Manual, Rev. 1.0, January 2014
General Rules:
1.
Commands are only in CAPITAL.
2.
CHK (2 ASCII char) can be enabled or disabled from both command and response.
3.
Weight data is 8-byte with dot and non-significant zeros on the left.
4.
Address (2 ASCII char) will be located in the structure, if not 00.
Command format:
A general description of the command is the following:
[ADR][COMMAND][CHK][CR][LF]
Response format with weight / force :
A general description of the response is the following:
[ADR][COMMAND][STATUS][SIGN][WEIGHT/FORCE][CHK][CR][LF]
Response format without weight / force
[ADR][COMMAND][STATUS][CHK][CR][LF]
Command Table:
A
Read all weight data immediately
B
Read Gross weight value immediately
C
Clear the tare memory
G
Read voltage value of DC power supply
I
Read current weight (indicated) value immediately
P
Print: Read the current stable weight value
Q
Load set points
R
Read set points
S
Read Status
T
Tare
U
Read digital inputs
V
Read digital outputs
W
Set/Reset digital outputs
X
Read current weight value in increased resolution immediately
Z
Zero
Status Table:
A
Ack, the command is operated successfully
D
Dynamic, unstable weight
E
Errors except of H, L, O, +, −.
H
High voltage detected
I
The weight is in range
L
Low voltage detected
N
Nack, the command couldn’t be operated
O
ADC out
S
Stable weight
X
Syntax error ( not recognized the received command )
+
Overload
−
Underload
Note:
CHK, CR and LF will not be shown in below data format descriptions in this section.