FT-10 Smart Process Indicator, Technical Manual, Rev. 1.0, January 2014

[036 0] Response Speed

0 : Modbus TCP Answer is sent immediately after Request is received.

1 : Modbus TCP Answer is delayed 20 msec after Request is received.
2 : Modbus TCP Answer is delayed 50 msec after Request is received.
This property is very helpful for slow PLC systems

11.1 Ethernet Parameters

There are 11 parameters for Ethernet network and Ethernet set up done by EtherX PC software over Local
Network Area as described in this section or You can entry from par. [ 03- ] blocks. EtherX PC software is
available in CD which is supplied together with the instrument.

Host Name

Device name of the instrument.
Default is ‘ ’.

IP Address

Obtain IP address manually.
Default is ‘192.168.16.250’.

Local Port

Ethernet connection port of the instrument.
Default is ‘502’.

Gateway

Network point that acts as an entrance to another network.
Default is ‘192.168.16.253’.

Subnet Mask

Describes IP address can be used in network.
Default is ‘255.255.255.0’.

Primary DNS

Obtain primary DNS manually.
Default is ‘208.67.222.222’.

Secondary DNS

Obtain secondary DNS manually.
Default is ‘208.67.220.220’.

Remote Connection

Automatic connection to any device on the network.
Default is ‘Disabled’.
Remote IP : IP address of the PC or Device to be connected automatically.
Remote Port : Ethernet connection point of PC or Device to be connected automatically.