FT-10 Smart Process Indicator, Technical Manual, Rev. 1.0, January 2014

10.2 GSDML Configuration

Profinet data structures of FT-10 PN includes 2 x Input 2 words and 2 x Output 2 words. GSDML
configuration for PLC programmers is shown in Figure 10.1.

Figure 10.1 - GSDML Configuration

10.3 Profinet Data Structure

FT-10 PN Output to PLC Input

Bitwise of a Dword:

Dword
(Only
read)

D31 D30 D29 D28 D27 D26 D25 D24 D23 D22 D21 D20 D19 D18 D17 D16

D15 D14 D13 D12 D11 D10 D9

D8

D7

D6

D5

D4

D3

D2

D1

D0



1

st

Dword

By default, Indicated weight value is represented.
To represent other weight or calibration status, refer to next Dword.

2

nd

Dword

Out
5

Out
4

Out
3

Out
2

Out
1

In
4

In
3

In
2

In
1

Error codes of FT-10
PN

Not in use

Zero
range

Gros
s
Net

MD Read command response

Cmd
Flg







FT-10 PN Output to PLC Input 2

nd

Dword