FT-10 Smart Process Indicator, Technical Manual, Rev. 1.0, January 2014

[12-] Filter

In this block the proper filter values according to the operating conditions can be entered. One of the

most important features of FT-1x series is viewing filter characteristic on the display and with the

help of this option, you can select the most suitable filter without exiting the programming mode.

[120 7 ] Filter

The filter value can be selected from 0 to 9 ( The minimum value of the filter at least 7 in normal
weighing applications). As you enter this parameter and press < Enter > key while [120 X] seen on
the display, the weight variation can be seen on the display. The value of the filter can be changed
by using <

> key and the weight variation for every value can be seen on the display. After

finishing the filter selection you can go to next step by pressing the < F > key.

5.4.3 Parallel Inputs and Outputs [13- ]

FT-10 has an optional up to 4 parallel inputs and up to 5 parallel outputs.

[130 0 ] Outputs

The outputs operate with respect to the weight value seen on the display.

At FT-10, FT-10 MB, FT-10 PB, FT-10 PN, FT-10 EN and FT-10 CO the outputs are programmed
as;

0 : No.
1 : ( Output1 = Sp1 ), (Output2 = Sp2 ), (Output3 = Sp3 ), (Output4 = Sp4 ), (Output5 = Sp5 )
2 : ( Output1 = Sp1 ), (Output2 = Sp2 ), (Output3 = Sp3 ), (Output4 = Sp4 ), (Output5 = Stable )
3 : ( Output1 = Sp1 ), (Output2 = Sp2 ), (Output3 = Sp3 ), (Output4 = Sp4 ), (Output5 = Error )
4 : Not used
5 : Functional outputs ( Refer to [ 7-- ] parameter group on

Page 36

)


At FT-10 AN the outputs are programmed as;

0 : No.
1 : ( Output1 = Sp1 ), (Output2 = Sp2 ), (Output3 = Sp3 ), (Output4 = Sp4 )
2 : ( Output1 = Sp1 ), (Output2 = Sp2 ), (Output3 = Sp3 ), (Output4 = Stable )
3 : ( Output1 = Sp1 ), (Output2 = Sp2 ), (Output3 = Sp3 ), (Output4 = Error )
4 : Not used
5 : Functional outputs ( Refer to [ 7-- ] parameter group on

Page 36

)

[131 0] Input 1

0 : Not used

1 : Zero

2 : Tare

3 : Clear 4 : Print

5 : Key lock

6 : Hold during active

7 : Peak during active

8 : Field bus input

[132 0] Input 2

0 : Not used

1 : Zero

2 : Tare

3 : Clear 4 : Print

5 : Key lock

6 : Hold during active

7 : Peak during active

8 : Field bus input

[133 0] Input 3 (only FT-10, FT-10 MB, FT-10 PB, FT-10 PN, FT-10 EN and FT-10 CO

0 : Not used

1 : Zero

2 : Tare

3 : Clear 4 : Print

5 : Key lock

6 : Hold during active

7 : Peak during active

8 : Field bus input

[134 0] Input 4 (only FT-10, FT-10 MB, FT-10 PB, FT-10 PN, FT-10 EN and FT-10 CO

0 : Not used

1 : Zero

2 : Tare

3 : Clear 4 : Print

5 : Key lock

6 : Hold during active

7 : Peak during active

8 : Field bus input