FT-10 Smart Process Indicator, Technical Manual, Rev. 1.0, January 2014

PLC Output to FT-10 PB Input 2

nd

Dword

Bit Number

2

rd

Dword descriptions

D31 … D24

Set / Reset digital outputs

D23 … D16

Expanded Commands List ( Refer to Table 9.1 )

D15 ... D11

Not in use












D10 … D6












D10 … D6












Command
List










(continuation
of previous
page)

Bin

Dec

Commands

00000

0

None command is activated

00001

1

Zero

00010

2

Tare

00011

3

Clear

00100

4

Print

00101

5

Adjust zero calibration

Calibration

00110

6

Adjust span calibration

(1)

00111

7

Total Load Cell Capacity

(1)

eCal
Coefficients
Refer to par.
[313]

01000

8

Average mV/V value

(1)

01001

9

Dead Load value

(1)

01010

10

Save the coefficients of eCal

01011
01110

11
14

Not used

01111

15

Set Point-1 Low

(1)

10000

16

Set Point-1 High

(1)

10001

17

Set Point-2 Low

(1)

10010

18

Set Point-2 High

(1)

10011

19

Set Point-3 Low

(1)

10100

20

Set Point-3 High

(1)

10101

21

Set Point-4 Low

(1)

10110

22

Set Point-4 High

(1)

10111

23

Set Point-5 Low

(1)

11000

24

Set Point-5 High

(1)

11111

31

Use the Expanded Command list ( Refer to Table 9.1 )

D5 ... D1

Read Data
Selection

00000

0

Indicated weight

00001

1

Gross weight

00010

2

Tare weight

00011

3

Calibration Status ( Refer to Table 9.1 )

00100
01110

4
14

Not used

01111

15

Set Point-1 Low

( 2 )

10000

16

Set Point-1 High

10001

17

Set Point-2 Low

( 2 )

10010

18

Set Point-2 High

10011

19

Set Point-3 Low

( 2 )

10100

20

Set Point-3 High

10101

21

Set Point-4 Low

( 2 )

10110

22

Set Point-4 High

10111

23

Set Point-5 Low

( 2 )

11000

24

Set Point-5 High

11111

31

Use the Expanded Command list ( Refer to Table 9.1 )

D0

New CMD

Toggle

Apply commands which are listed in this table


(1) Write this command after writing values to 1

st

Dword , then apply this command with New CMD

(2) Only set point low addresses are used if the set point is programmed as standard.