FT-10 Smart Process Indicator, Technical Manual, Rev. 1.0, January 2014


Figure 4.10

- Cross PC connection

Warning:

Connect the shield to the reference ground or shield pin of the power connector.

Warning:

Disconnect IndFace1X PC software before starting Profinet interfacing.

4.3.8 Ethernet Connection (only FT-10 EN )

Ethernet interface is used for data transfer to PC or PLC in the formats shown below.

Usage

Ethernet interface with PC or PLC

Data formats

Continuous, Fast Continuous, Printer Format, BSI Protocol,
Modbus TCP/IP High-Low,
Modbus TCP/IP Low-High

Ethernet

The Ethernet interface operates at 10Mbit, half duplex

Ethernet Connector pin configuration (RJ45)

Pin

Signal

DIR

Description

1

TX+

Out

Differential Ethernet transmit data +

2

TX−

Out

Differential Ethernet transmit data −

3

RX+

In

Differential Ethernet receive data +

6

RX−

In

Differential Ethernet receive data −

4

Not used

Terminated

5

Not used

Terminated

7

Not used

Terminated

8

Not used

Terminated

Shield

Chassis ground


The HUB connection cabling will be a direct connection as shown below:

Figure 4.11 - HUB connection

The PC connection cabling will be done via cross cable as shown below. IP address blocks and gateway
address of FT-10 and PC should be the same in cross connection.

Figure 4.12

- Cross PC connection