4.3.9 CANopen Connection (only FT-10 CO )

CANopen connection is done with 4 wires as indicated in Figure 4.13. The data line ends must be equipped
with 120 ohm bus terminating resistors.

Figure 4.13 - FT-10 CO serial interface connections

CANopen Connector pin configuration (DB9M)

Pin

Signal

Description

1

-

-

2

CAN_L

-

3

CAN_GND

-

4

-

-

5

CAN_SHIELD

-

6

-

-

7

CAN_H

-

8

-

-

9

-

-

Housing

Cable Shield

-

Warning:

Connect the shield to the reference ground.

Warning:

Disconnect IndFace1X PC software before starting CANopen interfacing.