] profibus (only ft-10 pb) – Flintec FT-10xx User Manual

Page 28

Advertising
background image

FT-10 Smart Process Indicator, Technical Manual, Rev. 1.0, January 2014

[043 0] Print Method

0 : Printing via key.

1 : Auto print.
2 : Print interlock

Explanation:

If this parameter is selected as auto print, the data will automatically be printed when the

data exceeds minimum print value and becomes stable. The weight value should decrease under minimum
print value to reprint. If this parameter is selected as print interlock, after printing the weight must be changed
to reprint.

[044 XY] Line Feed Before Printing

X=0,1

: 0 means the forward feeding and 1 means the backward feeding.

Y=0,1,2….9

: Enter the number of the feed lines before data printing

[045 XY] Line Feed After Printing

X=0,1

: 0 means the forward feeding and 1 means the backward feeding.

Y=0,1,2

….9

: Enter the number of the feed lines after data printing

[046 0] Form Feed

0 : No Form Feed
1 : After printing, the printer will go to next page automatically.

[047 3] Space on the left

Here you can enter the number to shift the printout to the right on the paper.
Available values are from 0 to 9.

[048 1] Quantity of Copies

X = 1,2….9 : Enter the label quantity for each weighing.

Note:

This function is valid only for 040 = 2 or 3.

[05-] Profibus (Only FT-10 PB)

This sub-block includes the parameters related with the Profibus interfaces of FT-10 indicator.

[050 0 ] Data Format

0 : Signed 32 bit integer, no decimal point implied
1 : 32 bit float, decimal point implied

[051 000] Rack Address

The Profibus rack address of FT-10 will be entered via keypad between 001 to 126.

Advertising
This manual is related to the following products: