FT-10 Smart Process Indicator, Technical Manual, Rev. 1.0, January 2014

5.5.2 Digital Output Functions [70-]

In this block, the digital outputs are programmed for the functions indicated in the table below.

Threshold Output :

2 set point values are entered. SP1
is the point that the output goes
active when the weight increased
from SP1_H. SP1_L is the point that
the output drops to passive state
when the weight decreased to
SP1_L.
Inverse function is available.

Window Output:

2 set point values are entered. The
output is active when the weight is
between SP1_L and SP1_H. Inverse
function is available.

Table 5.1 - Digital output functions

[700 0] Output 1

Refer to Table 5.1 to select the output function.

0 : No function on output 1
1 : Threshold (Active High)
2 : Threshold (Active Low)
3 : Window (Active High)
4 : Window (Active Low)
5 : Fieldbus output

[701 0] Output 2

Refer to Table 5.1 to select the output function.

0 : No function on output 2
1 : Threshold (Active High)
2 : Threshold (Active Low)
3 : Window (Active High)
4 : Window (Active Low)
5 : Fieldbus output

[702 0] Output 3

Refer to Table 5.1 to select the output function.

0 : No function on output 3
1 : Threshold (Active High)
2 : Threshold (Active Low)
3 : Window (Active High)
4 : Window (Active Low)
5 : Fieldbus output

[703 0] Output 4

Refer to Table 5.1 to select the output function.

0 : No function on output 4
1 : Threshold (Active High)
2 : Threshold (Active Low)
3 : Window (Active High)
4 : Window (Active Low)
5 : Fieldbus output