Motload commands – Artesyn MOTLoad Firmware Package User's Manual (February 2015) User Manual
Page 105
MOTLoad Commands
MOTLoad Firmware Package User’s Manual (6806800C24D)
105
Notes
1. Size option (-n) is specified in bytes. Devices typically set protection at the sector level.
Minimum number of bytes that are set to unprotected is determined by sector size and
Flash configuration.
2. Since not all Flash devices support a software protection mechanism, not all MOTLoad
products include the command.
Error Messages
flashUnlock(): open(<device>) failed, errno = <value>
Unable to open specified Flash device.
flashUnlock(): ioctl(101) failed, errno = <value>
Unable to read Flash configuration.
flashUnlock(): ioctl(104) failed, errno = <value>
Unable to invoke Flash driver.
Flash Memory PreProgramming Error: Address-Alignment
Flash addresses not aligned.
Flash Memory PreProgramming Error: Address-Range
Flash addresses out of range.
Flash Memory PreProgramming Error: Unexpected-Manufacturer-Identifier
Manufacturer ID not as expected.
Flash Memory PreProgramming Error: Unexpected-Device-Identifier
Device identifier not as expected.
Flash Memory Programming Error: Lock-Protected-Sector(s)-Detected
Unlockable Sector(s) Detected.