19 cm, Motload commands – Artesyn MOTLoad Firmware Package User's Manual (February 2015) User Manual
Page 65
MOTLoad Commands
MOTLoad Firmware Package User’s Manual (6806800C24D)
65
3.1.19 cm
Name
cm—mirrors the debug port to a second onboard serial port that is specified by the command
options.
Synopsis
cm [-bPd] [-dPs] [-pPs] [-sPd] [-wPd]
Parameters
-b Pd: Baud Rate (Default = 9600)
-d Ps: Serial-Port Device Name (Default = /dev/com2)
-p Ps: Parity (e/o) (Default = No)
-s Pd: Stop Bits (1/2) (Default = 1)
-w Pd: Word Size (7/8) (Default = 8)
Example
The following example indicates a typical display when using the cm command.
MOTLoad> cm
Concurrent Mode Activated
MOTLoad>
Error Messages
cm(): ioctl(<value>) failed, errno = <value>
Unable to set specified COM port.
cm(): device settings argument error
Invalid setting for specified COM port.
cm(): open(<device>) failed, errno = <value>
Couldn't open port.