MOTLoad Commands

MOTLoad Firmware Package User’s Manual (6806800C24D)

166

3.1.83 stop

Name

stop—turns off the oscillator in the RTC chip. The board is shipped with the RTC oscillator
stopped to minimize current drain from the onchip battery. Normal cold start of the board with
the MOTLoad Flash devices installed gives the RTC a "kick start" to begin oscillation.
Use set command to restart the clock.

Synopsis

stop

Parameters

No parameters

Example

The following example indicates a typical display when using the stop command.

MOTLoad> stop

(Clock is in Battery Save Mode)

MOTLoad>

Error Messages

timeStop(): open(<device>) failed, errno = <value>

Failed to open timekeeper.

timeStop(): ioctl(110) failed, errno = <value>

Failed to stop clock.

See Also

set