106 testrtcrollover, 106testrtcrollover, Testrtcrollover – Artesyn MOTLoad Firmware Package User's Manual (February 2015) User Manual
Page 194: Motload commands
MOTLoad Commands
MOTLoad Firmware Package User’s Manual (6806800C24D)
194
3.1.106 testRtcRollOver
Name
testRtcRollOver—verifies the ’roll-over’ operation of the Real Time Clock (RTC). The test
proceeds as follows: (1) Check the RTC STOP bit, and if set, turn on the RTC CLOCK. (2) Set the
RTC date to “December 31, 1999 at 23 hours, 59 minutes, and 59 seconds. (3) Verify the RTC
day/month/year and hours/minutes/seconds have rolled over. (4) Restore the original
day/month/year and hours/minutes/seconds values. (5) If the RTC STOP bit, which disables the
RTC.
Synopsis
testRtcRollOver [-d]
Parameters
-d Ps: Device Name (Default = /dev/rtc)
Example
The following example indicates a typical display when using the testRtcAlarm command.
MOTLoad> testRtcRollOver
See Also