106 testrtcrollover, 106testrtcrollover, Testrtcrollover – Artesyn MOTLoad Firmware Package User's Manual (February 2015) User Manual

Page 194: Motload commands

Advertising
background image

MOTLoad Commands

MOTLoad Firmware Package User’s Manual (6806800C24D)

194

3.1.106 testRtcRollOver

Name

testRtcRollOver—verifies the ’roll-over’ operation of the Real Time Clock (RTC). The test
proceeds as follows: (1) Check the RTC STOP bit, and if set, turn on the RTC CLOCK. (2) Set the
RTC date to “December 31, 1999 at 23 hours, 59 minutes, and 59 seconds. (3) Verify the RTC
day/month/year and hours/minutes/seconds have rolled over. (4) Restore the original
day/month/year and hours/minutes/seconds values. (5) If the RTC STOP bit, which disables the
RTC.

Synopsis

testRtcRollOver [-d]

Parameters

-d Ps: Device Name (Default = /dev/rtc)

Example

The following example indicates a typical display when using the testRtcAlarm command.

MOTLoad> testRtcRollOver

See Also

testRtcAlarm

,

testRtcTick

,

testRtcReset

Advertising