MOTLoad Commands

MOTLoad Firmware Package User’s Manual (6806800C24D)

144

3.1.70 pciShow

Name

pciShow—displays the entire PCI configuration header register contents of each PCI device, as
specified by the command line arguments.

Synopsis

pciShow [-b] [-d] [-f] [-i] [-n] [-s] [-x]

Parameters

-b Pd: Bus Number (Default = 0)

-d Pd: Device Number (Default = 0)

-f Pd: Function Number (Default = 0)

-i Pd: Bus Instance (Default = 0)

-m 0 : Multi-Function Device Rule Mode

-p 0 : Probe

-s 0 : Short Display Mode

Note pciShow without any parameters displays the PCI configuration header register

contents of each on-board PCI device only. On-board PCI devices include PCI controllers and
PCI-to-PCI bridges that statically reside on the PCI bus(es) of the baseboard. pciShow with the
–p parameter causes MOTLoad to probe the PCI bus(es) and displays the PCI configuration
header register contents of all PCI devices, which include on-board PCI devices and external PCI
devices that are located on a PMCSpan and/or PMC site.

Example

The following example indicates a typical display when using the pciShow commands.

MOTLoad> pciShow

Instance/Bus/Device/Function: 00 00 06 00

Vendor/Device Identifier : 8086 B154

Class : 06 Bridge Controller/Device

Sublcass : 04 PCI-to-PCI Bridge

0000 80 86 B1 54 00 07 02 B0 00 00 04 06 08 80 01 00 ...T..