H3C Technologies H3C S10500 Series Switches User Manual

Page 125

Advertising
background image

110

To do...

Use the command...

Remarks

Enter public network IGMP view or
VPN instance IGMP view

igmp [ vpn-instance
vpn-instance-name ]

Configure the IGMP querier’s
robustness variable

robust-count robust-value

Required
2 by default

Configure the startup query
interval

startup-query-interval interval

Required
By default, the startup query

interval is 1/4 of the “IGMP

general query interval”.

Configure the startup query count

startup-query-count value

Required
By default, the startup query count

is set to the IGMP querier’s

robustness variable.

Configure the IGMP general query
interval

timer query interval

Required
60 seconds by default

Configure the maximum response
time for IGMP general queries

max-response-time interval

Required
10 seconds by default

Configure the IGMP last-member
query interval

last-member-query-interval
interval

Required
1 second by default

Configure the other querier present
interval

timer other-querier-present
interval

Required
By default, the other querier
present interval is [ IGMP general

query interval ] × [ IGMP

robustness variable ] + [ maximum

response time for IGMP general
queries ] / 2.

Configuring IGMP query and response parameters on an interface

Follow these steps to configure IGMP query and response parameters on an interface:

To do...

Use the command...

Remarks

Enter system view

system-view

Enter interface view

interface interface-type
interface-number

Configure the IGMP querier’s
robustness variable

igmp robust-count robust-value

Required
2 by default

Configure the startup query
interval

igmp startup-query-interval
interval

Required
By default, the startup query
interval is 1/4 of the “IGMP

general query interval”.

Configure the startup query count

igmp startup-query-count value

Required
By default, the startup query count
is set to the IGMP querier’s

robustness variable.

Advertising