VPN-Instance: public net

Interface NbrCnt HelloInt DR-Pri DR-Address

Vlan100 0 30 1 10.110.1.1 (local)

Vlan101 1 30 1 192.168.1.2

Vlan102 1 30 1 192.168.9.2

To view the BSR election information and the locally configured C-RP information in effect on a switch, use
the display pim bsr-info command. For example:
# View the BSR information and the locally configured C-RP information in effect on Switch A.

[SwitchA] display pim bsr-info

VPN-Instance: public net

Elected BSR Address: 192.168.9.2

Priority: 20

Hash mask length: 32

State: Accept Preferred

Scope: Not scoped

Uptime: 00:40:40

Expires: 00:01:42

# View the BSR information and the locally configured C-RP information in effect on Switch D.

[SwitchD] display pim bsr-info

VPN-Instance: public net

Elected BSR Address: 192.168.9.2

Priority: 20

Hash mask length: 32

State: Accept Preferred

Scope: Not scoped

Uptime: 00:05:26

Expires: 00:01:45

Candidate BSR Address: 192.168.4.2

Priority: 10

Hash mask length: 32

State: Candidate

Scope: Not scoped

Candidate RP: 192.168.4.2(Vlan-interface105)

Priority: 192

HoldTime: 150

Advertisement Interval: 60

Next advertisement scheduled at: 00:00:34

# View the BSR information and the locally configured C-RP information in effect on Switch E.

[SwitchE] display pim bsr-info

VPN-Instance: public net

Elected BSR Address: 192.168.9.2

Priority: 20

Hash mask length: 32

State: Elected

Scope: Not scoped

Uptime: 00:01:18

Advertising