178

Figure 53 Network diagram for PIM-DM configuration

Ethern

et

E

th

e

rnet

E

thernet

N1

N2

Vl

an

-in

t102

Vlan-

int1

02

Vlan-

in

t10

3

Vl

an-

int103

Device

Interface

IP address

Device

Interface

IP address

Switch A

Vlan-int100

10.110.1.1/24

Switch D

Vlan-int300

10.110.5.1/24

Vlan-int103

192.168.1.1/24

Vlan-int103

192.168.1.2/24

Switch B

Vlan-int200

10.110.2.1/24

Vlan-int101

192.168.2.2/24

Vlan-int101

192.168.2.1/24

Vlan-int102

192.168.3.2/24

Switch C

Vlan-int200

10.110.2.2/24

Vlan-int102

192.168.3.1/24

Configuration procedure

1.

Configure IP addresses and unicast routing.

Configure the IP address and subnet mask for each interface as per

Figure 53

. (Details not shown)

Configure OSPF on the switches in the PIM-DM domain to ensure network-layer reachability among them.

(Details not shown)

2.

Enable IP multicast routing, and enable PIM-DM and IGMP.

# Enable IP multicast routing on Switch A, enable PIM-DM on each interface, and enable IGMP on
VLAN-interface 100, which connects Switch A to the stub network.

<SwitchA> system-view

[SwitchA] multicast routing-enable

[SwitchA] interface vlan-interface 100

[SwitchA-Vlan-interface100] igmp enable

[SwitchA-Vlan-interface100] pim dm

[SwitchA-Vlan-interface100] quit

[SwitchA] interface vlan-interface 103

[SwitchA-Vlan-interface103] pim dm

[SwitchA-Vlan-interface103] quit