Furuno RC-1500-1T User Manual

Page 144

Advertising
background image

7-4

Default: ABLE

**

Auto ack setup

**

COMPLY TYPE

: ABLE

UNABLE REASON :

NO REASON GIVEN

POSITION CALL

: OFF

POLLING CALL

: ON

ABLE

UNABLE

Choose ABLE or UNABLE as automatic
acknowledgement reply to Individual, Position
and Polling messages.

Note: Automatic acknowledge is automatically

disabled when Rx message contains error,
as required by law. Further, automatic
acknowledge is disabled in case of OFF
HOOK.

Automatic acknowledge of Position or
Polling request is not available when
UNABLE is selected.

Default: NO REASON

NO REASON

BUSY

EQUIP DISABLED

MODE NOT USABLE

CH NOT USABLE

Sets reason for UNABLE.

Note: This menu is the same as manual

acknowledgement. EQUIPMENT
DISABLED is shown in messages when
EQUIP DISABLED is selected.

Default: ON

Overrides/follows AUTO ACK setting
in case of position.
OFF: Disables automatic

acknowledgement of position
request.

ON: Enables automatic

acknowledgement of position
request.

[ENT] key

[ENT] key

[ENT] key

[ENT] key

ON

OFF

Default: ON

Overrides/follows AUTO ACK setting
in case of polling.
OFF: Disables automatic

acknowledgement of polling
request.

ON: Enables automatic

acknowledgement of polling
request.

ON

OFF

or
to set.

or
to set.

or
to set.

or
to set.

Advertising