SP - 11

SPECIFICATIONS OF THE AC/DC CHANGE-OVER UNIT

(RADIO SWITCH BOX)

1. BATTERY CHARGER (BC-6158)

(1) Applicable Battery

200AH Normal ship battery

(2) Power Source

100/110/115/220/230 VAC, 1 phase, 60 Hz or 24 VDC

(3) Output for Battery

24 VDC, 30 A nominal

(4) Charge/discharge Meter

built in the radio console panel

(5) Control Panel

built in the radio console

2. RECTIFIER (PR-850AR)

(1) Power Source

100/110/200/220 VAC, 1 phase, 50-60 Hz or 24 VDC

(2) Input Current

15 A or less (AC input), 30 A or less (DC input)

(3) Rush Current

80 A or less

(4) Output Voltage

DC24 V ±10%, 30 A

(5) Peak Output Current

60 A (60 A output with 1 min AC or 40 A within 1 min DC)

(6) Ripple Voltage

100 mVp-p or less

(7) Insulation Resistance

500 VDC, 50 M

or more between AC input and chassis

3. RECTIFIER (PR-300)

(1) Power Source

100/110/200/220 VAC, 1 phase, 50-60 Hz or 24 VDC

(2) Input Current

2 A or less (AC input), 3.1 A or less (DC input)

(8) Rush Current

80 A or less

(3) Output Voltage

24 VDC ±10%, 7.5 A

(4) Peak Output Current

20 A (10 A output within 2H or 20 A within 15 min)

(5) Ripple Voltage

100 mVp-p or less

(9) Insulation Resistance

500 VDC, 50 M

or more between AC input and chassis